Seal Support System
						
					
					
						
						
							
							
							
								
								Heat Exchanges
		
								Super Thermosyphon Systems – Series STV – 100 & HE 200 
								
						    		- Performance Limits  HE -100 HE 200
		                                
		                                    - Capacity: …………………………………………………    7.5 Ltrs      10 Ltr
- Heat Transfer area of cooling coil……………  0.5 m²        1.0 m²
- Design Pressure of cooling coil ………………  45 Kg         80 Kg 
- Working Pressure of cooling coil…………….  35 Kg         65 Kg 
- Design Pressure of Shell   ………………………..         30 Kg         30 Kg
- Working Pressure of Shell  ………………………        15 Kg          20 Kg
 
- Metal Parts 
		                                
		                                    - Heat Exchanger Shell : Carbon Steel / SS 316/SS3044
- Cooling Coil: SS 304 / SS 316
- Secondary Seal: Viton 
 
- Connection Size
		                                
		                                    - Buffer fluid Inlet …….………     A  ½” NPT
- Buffer fluid Outlet ….………     B ½ NPT
- Cooling water Inlet………….    C 3/4” NPT
- Cooling water Outlet ……… D 3/4” NPT
- Vent ………..………………………       E – ¼: NPT
- Drain ………………………………     F –1 ¼” NPT
 
 	
						 
					 		
				
			 
			
	
			
		
		0