Seal Support System
Hand Pump
Super Hand Pump Series – HP 100
- Performance Limits  HE -100 HE 200
								        
- Capacity: …………………………………. 1.5 Ltrs
 - Operating Temperature…………… 80°C
 - Design Pressure ……………………… 30 Kg
 - Delivery Pressure…………….………. 25 Kg
 - Displaced Volume …………………… 15cc/Stroke
 
 - Connection Size
								        
- Size …….……… ¼ ” NPT
 
 
								    Super Hand Pump HP 100 is specially made for Thermosyphon Vessel. 
This is normally recommended for API Plan 53 or API Plan 54. The function of the 
 Feed pump is to recharge the Thermosyphon Vessel with additional quantity of 
barrier fluid, when Thermosyphon is under pressure and Liquid level is low.
 This is caused due to mech.Seal failure or due to vapourisation